AMI Codes-II CC

Colorimetric process analyzer (DPD-method) for measurement and dosing control of disinfectants such as free chlorine, monochloramine, total residual chlorine and combined chlorine.

  • For the continuous online determination of disinfectants based on the DPD colorimetric method (EN ISO 7393-2; APHA 4500-Cl G).

  • Measurement values : free chlorine, monochloramine, total residual chlorine, combined chlorine, flow and if installed pH and temperature.

  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.

  • Integrated pH measurement with temperature compensation (available as option).

  • All usual dosing devices for disinfectants and pH control can be connected either through relays or analog output signals. Two independent controllers can operate simultaneously.

 

Seperate chemical cleaning module available as accessory.

Image

Specifications

Disinfectant measurement

Measuring range [ppm]

Accuracy

Free Chlorine, monochlorine, total residual chlorine

0.00

1.00

±0.01 ppm

1.00

3.00

±0.06 ppm

3.00

5.00

±0.2   ppm

Combined chlorine

Calculated difference of total residual chlorine and free chlorine.

Measurement time

2 min.

Cycle time free chlorine

1 ... 12 min.

Cycle time total residual chlorine

6 ... 60 min.

pH measuring range

2 ... 12

Temperature measuring range

-30 ... 100 °C

Transmitter Specifications

Power Supply

100-240 VAC (±10%), 50/60Hz or 10-36 VDC

Power consumption

max. 35 VA

Sample conditions

Water consumption

min. 10 l/h

Water inlet pressure

0.15 ... 2 bar

Sample temperature

5 ... 50 °C

Panel

Dimension

400 x 850 x 200 mm

Material

PVC

Weight

9.0 kg

Heeft u vragen of wilt u een offerte?